High temperature Clamp on Transducer |
|
|
Mounting bracket Clamp on Transducer |
|
|
|
|
Main Unit |
Transducer |
Protection Level |
IP65 |
IP68 |
Humidity |
≤8 5 % RH |
Temperature |
-20~60℃ |
-30℃~160℃ |
|
|
|
Accuracy |
≤ 1 % |
Velocity Range |
0~±10m/s,Bi-directional measurement |
Pipe Size |
DN32~DN6000mm |
Temperature |
-30℃~160℃ |
Type of Liquid |
Single liquid that can transmit ultrasound,such as water,sea water, sewage,oil,alcohol, etc. |
Pipe Material |
Steel, stainless steel, cast iron, copper, PVC , Aluminum ,glass steel, etc. Liner is allowed. |
Signal Output |
1 way 4-20mA output; 1 way OCT pulse output; 1 way Relay output; |
Signal Input |
3 way 4-20mA input, achieve to heat measurement by connecting PT100 platinum resistor. |
Interface |
RS485 , support MODBUS |
Data Storage |
SD card regularly store the pre-set results(optional) |
Power Supply |
DC8~36V or AC85~264 V |
|
|
|
|
|
• Built-in magnet, easy to be absorbed on pipe • Protection Level: IP68 • Measuring range: DN32~DN6000 • Temperature range: -30~90℃ |
|
Type |
Model |
Measuring Range |
Temperature |
Dimension |
Small Size |
TS-2 |
DN32~DN100 |
-30~90℃ |
45x25x28mm |
Medium Size |
TM-1 |
DN50~DN700 |
-30~90℃ |
64x39x44mm |
Large Size |
TL-1 |
DN300~DN6000 |
-30~90℃ |
97x54x53mm |
|
High Temperature Clamp on Transducer |
|
|
• Built-in magnet, easy to be absorbed on pipe • Protection Level: IP68 • Measuring range: DN32~DN6000 • Temperature range: -30~160°C |
|
Type |
Model |
Measuring Range |
Temperature |
Dimension |
Small Size |
TS-2-HT |
DN15~DN100 |
-30~160℃ |
45x25x28mm |
Medium Size |
TM-1-HT |
DN50~DN700 |
-30~160℃ |
64x39x44mm |
Large Size |
TL-1-HT |
DN300~DN6000 |
-30~160℃ |
97x54x53mm |
|
Mounting Bracket Transducer |
|
|
• Improve installation efficiency and accuracy • Protection Level: IP68 • Measuring range: DN32~DN700 • Temperature range: -30~160℃ |
|
Type |
Model |
Measuring Range |
Temperature |
Dimension |
Sm all Size |
HS |
DN15~DN100 |
-40~90℃ |
318x59x85mm |
Medium Size |
HM |
DN50~DN700 |
-40~90℃ |
568x59x85mm |
Extended |
EB-1 |
>DN300 |
-40~90℃ |
88x59x49mm |
Small Size |
HS-HT |
DN15~DN100 |
-40~160℃ |
318x59x145mm |
Medium Size |
HM-HT |
DN50~DN300 |
-40~160℃ |
568x59x145mm |
Extended |
EB-1-HT |
>DN300 |
-40~160℃ |
88x59x49mm |
|