Items |
Performance and Parameter |
Main Unit |
Principle |
transit-time ultrasonic flowmeter |
Accuracy |
Accuracy :over 1%-2%; Repeatability: over 0.2% |
Display |
4 line x 16 character LCD with backlight |
Dimension |
200*93*33cm: 390g |
Operation |
Support 16 key light touch keyboard and the Simulation keyboard software |
Data interface |
Insulate RS232 serial interface, upgrade the flew meter software by computer, support the MODBUS, etc. |
Signal Output |
1 way OCT output |
Special Cable |
Twisted-pair cable; Select the RS232 communication; Generally, the standard is 5m*2, optional 10m*2 |
Pipe Condition |
Pipe Material |
Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed. |
Pipe Diameter |
DN 15---6000mm |
Straight length pipe |
Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump. |
Measuring Medium |
Type of Liquid |
Water ; Ultra-pure liquids; Solvents and other liquids |
Temperature |
Standard Transducer: -30--90℃; High-temperature transducer: -40--160℃ |
Turbidity |
under 10000ppm and less bubble |
Flow rate |
0--±10m/s |
Flow Direction |
Measuring two (plus-minis) direction of flow rate |
Working Environment |
Temperature |
Main Unit: -20--60℃ |
Flow transducer: -40--160℃; Temperature transducer: according to the customer’s demands. |
Humidity |
Main Unit: 85% RH |
Power Supply |
AC 110V-240V |