Focvpg Series Vortex Precession Gas Flowmeter

Vortex Precession Gas Flowmeter

Focvpg Series Vortex Precession Gas Flowmeter

Huahai M&C for Thirteen Years|Profession Famous Brand |2017 Overall Upgrade|New Products Solemn On-Line


Vortex Precession Gas Flowmeter

Performance characteristics of Focvpg Series Vortex Precession Gas Flowmeter

Persistence is the key to success |Manufacture Huahai High Quality Products
Bring New Products to Market in 2017

Vortex Precession Gas Flowmeter

Vortex Precession Gas Flowmeter

Product • Structure Detail Drawing

Product Internal Structure|Decomposition Analysis|Just to give you a better understanding of the product
Committed to provide solution for field instruments

Vortex Precession Gas Flowmeter

Product • performance index

Various parameters for you to choose|HUAHAI instruments strive for excellence
Committed to provide solution for field instruments

Vortex Precession Gas Flowmeter
Name Focvpg Series Vortex Precession Gas Flowmeter
Nominal diameter (mm) DN25-DN200
Applicable medium Gas
Accuracy class 1.0% 、1.5%
Pressure class PN1.6MPa 、 PN2.5Pa 、PN4.0MPa
Medium temperature -20~80℃
Ambient temperature -30~60℃
Relative humidity 5%~95%
Atmospheric pressure 86KPa~106KPa
Temperature and pressure compensation User selection
Working power supply External power supply:24V DC Internal power supply:3.6V lithium battery
Power consumption of complete instrument External power supply: Internal power supply:
Output signal Frequency signal 4-20mA current signal
Communication RS485 communication、Modbus communication,
Can transmit instantaneous flow, accumulative flow,
pressure and temperature parameters
Housing material Aluminum alloy housing(PN≤1.6Mpa)
stainless steel shell(PN≤4.0Mpa)
PN>4.0Mpa for special specifications
Installation method Flange installation
Explosion-proof mark ExdIIBT4
Protection class IP65
Vortex Precession Gas Flowmeter
Nominal diameter(mm) Measuring range(m³/h)
DN25 2.5-30
DN32 4.5-60
DN50 10-150
DN80 28-400
DN100 50-800
DN150 150-2250
DN200 360-3600

Product • Diagram of Outline dimension

Outline and installation dimensions|Huahai instruments show you one by one
Committed to provide solution for field instruments

Vortex Precession Gas Flowmeter
Vortex Precession Gas Flowmeter
flowmeter with aluminum alloy housing
Nominal
diameter
DN(mm)
Pressure
class
(PN)
Total
installation
length
L(mm)
Total
installation
height
H(mm)
Flange
outer
diameter
D(mm)
Diameter
of bolt
hole center
circle
K(mm)
Number of
bolt hole
n
Bolt hole
diameter
d
20 1.6MPa 160 410 105 75 4-Φ14
25 1.6MPa 180 420 115 85 4-Φ14
32 1.6MPa 200 430 140 100 4-Φ18
50 1.6MPa 232 440 165 125 4-Φ18
80 1.6MPa 330 490 200 160 8-Φ18
100 1.6MPa 413 510 220 180 8-Φ18
150 1.6MPa 575 560 285 240 8-Φ22
200 1.6MPa 700 620 340 295 12-Φ22
Note: 1. All data on the above table is only based on standard Vortex Precession flowmeter;
2. The pressure and caliber not listed in the table are special specifications,special instructions;
3. Above dimensions perform HG20593-2009 flange standard, special instructions;
Vortex Precession Gas Flowmeter
Vortex Precession Gas Flowmeter
Outline and installation dimensions table of Vortex Precession flowmeter with stainless steel housing
Nominal
diameter
DN(mm)
Pressure
class
(PN)
Total
installation
length
L(mm)
Total
installation
height
H(mm)
Flange
outer
diameter
D(mm)
Diameter
of bolt
hole center
circle
K(mm)
Number of
bolt hole
n
Bolt hole
diameter
d
20 4.0MPa 200 300 105 75 4-Φ14
25 4.0MPa 200 300 115 85 4-Φ14
32 4.0MPa 200 360 140 100 4-Φ18
50 4.0MPa 230 370 165 125 4-Φ18
50 6.3MPa 240 390 180 135 4-Φ22
80 1.6MPa 330 420 200 160 8-Φ18
80 6.3MPa 330 430 215 170 8-Φ22
100 1.6MPa 410 485 220 180 8-Φ18
150 1.6MPa 570 510 285 240 8-Φ22
200 1.6MPa 700 570 340 295 12-Φ22
Note: 1. All data on the above table is only based on standard Vortex Precession flowmeter;
2. The pressure and caliber not listed in the table are special specifications,special instructions;
3. Above dimensions perform HG20593-2009 flange standard, special instructions;

Product • Wiring Diagram

Multiple wiring modes|Huahai instruments show you one by one
Committed to provide solution for field instruments

Vortex Precession Gas Flowmeter Vortex Precession Gas Flowmeter
1. Two-wire system 4~20mA output
报警Alarm   频率Frequency   电流Current   通讯Communication    用户设备User facilities
2. Three-wire system 4~20mA output
报警Alarm   频率Frequency   电流Current   通讯Communication    用户设备User facilities
  Vortex Precession Gas Flowmeter
3. 24V frequency, pulse output   4. Note: the negative pole of the frequency output and the negative pole of the DC 24V share one terminal;Frequency, pulse output must be three-wire system wiring.The wiring is shown below, two-wire system does not support frequency, pulse output.
    报警Alarm   频率Frequency   电流Current   通讯Communication    用户设备User facilities
Vortex Precession Gas Flowmeter Vortex Precession Gas Flowmeter
5. RS485 Communication Interface Output(Must be three-wire system wiring) 6. Alarm Signal Output(Must be three-wire system wiring)
报警Alarm   频率Frequency   电流Current   通讯Communication    用户设备User facilities

Vortex Precession Gas Flowmeter

Enterprise honorary qualification

Vortex Precession Gas Flowmeter
Vortex Precession Gas Flowmeter
Vortex Precession Gas Flowmeter

Picture of electromagnetic flow meter equipment

Vortex Precession Gas Flowmeter

Picture of client using HUAHAI instruments

Vortex Precession Gas Flowmeter