Foctur tri-clamp type liquid turbine flowmeter

Foctur series turbine flow meter

Foctur series turbine flow meter

Huahai M&C for Thirteen Years|Profession Famous Brand |2017 Overall Upgrade|New Products Solemn On-Line

Foctur series turbine flow meter

 

Performance characteristics of Foctur series turbine flow meter

Persistence is the key to success |Manufacture Huahai High Quality Products
Bring New Products to Market in 2017

Foctur series turbine flow meter
Foctur series turbine flow meter

 

Product • Structure Detail Drawing

Product Internal Structure|Decomposition Analysis|Just to give you a better understanding of the product
Committed to provide solution for field instruments

Foctur series turbine flow meter

 

Product • performance index

Various parameters for you to choose|HUAHAI instruments strive for excellence
Committed to provide solution for field instruments

Foctur series turbine flow meter
Measuring medium No impurities, no strong corrosive, low viscosity liquid
perform standard Turbine flow sensor(JB/T9246-1999)
Verification regulation Turbine flowmeter(JJG1037-2008)
Instrument caliber
and connection mode
Flange connection
type
DN15-DN200
Thread connection
type
DN4-DN50
Clamp connection
type
DN25-DN50
Flange standard Conventional standard GB/T9113-2000
Other standards International pipe flange standard Such as the German standard DIN,、American Standard ANSI、Japanese standard JIS
Domestic pipe flange standard Such as the standard of the ministry of chemical industry、the standard of the ministry of machinery
Thread specification Conventional specification British pipe thread (external thread)
Other specifications Internal thread,、NPT thread, etc.
Accuracy class and corresponding repeatability Accuracy class ±1%R ±0.5%R ±0.2%R(need special order)
Linearity ≤0.15% ≤0.1% ≤0.03%
Range ratio 1:10; 1:15; 1:20
Instrument material 304 Stainless steel;316 Stainless steel
Medium Temperature(℃) -20℃~+110℃
Conditions of verification Environmental conditions Ambient temperature 20℃
Relative humidity 65%
verification device liquid flow verification device with standard meter method liquid flow verification device with Static mass method
Conditions of Use Ambient temperature -20℃~+60℃ Relative humidity 5%~90%
Atmospheric pressure 86Kpa~106Kpa
output signal Pulse frequency signal
two-wire system 4-20mA DC current signal
485communication
Power supply 24V DC
transmission distance ≤1000m
Signal line interface Basic type: Hersman joint, Explosion-proof type: internal thread M20*1.5
Explosion-proof class Basic type: Non-explosion-proof products, Explosion-proof type:Exd II CT6 Gb
Protection class IP65

Foctur series turbine flow meter
Instrument Diameter
(mm)
Normal flow range
(m3/h)
Extended Flow Range
(m3/h)
Instrument Diameter
(mm)
Normal flow range
(m3/h)
Extended Flow Range
(m3/h)
DN4 0.04~0.25 0.04~0.4 DN50 4~40 2~40
DN6 0.1~0.6 0.06~0.6 DN65 7~70 4~70
DN10 0.2~1.2 0.15~1.5 DN80 10~100 5~100
DN15 0.6~6 0.4~8 DN100 20~200 10~200
DN20 0.8~8 0.45~9 DN125 25~250 13~250
DN25 1~10 0.5~10 DN150 30~300 15~300
DN32 1.5~15 0.8~15 DN200 80~800 40~800
DN40 2~20 1~20      

Foctur series turbine flow meter

 

1.Flange connection type

Foctur series turbine flow meter Instrument
caliber
(mm)
Nominal
pressure
(Mpa)
L
(mm)
H
(mm)
D
(mm)
D1
(mm)
D
(mm)
n T
(mm)
DN15 4.0Mpa 75 300 95 65 14 4 14
DN20 4.0Mpa 90 305 105 75 14 4 16
DN25 4.0Mpa 100 310 115 85 14 4 16
DN32 4.0Mpa 140 325 140 100 18 4 18
DN40 4.0Mpa 140 335 150 110 18 4 18
DN50 4.0Mpa 150 350 165 125 18 4 20
DN65 1.6Mpa 180 365 185 145 18 4 20
DN80 1.6Mpa 200 380 200 160 18 8 20
DN100 1.6Mpa 220 400 220 180 18 8 22
DN125 1.6Mpa 250 430 250 210 18 8 22
DN150 1.6Mpa 300 460 285 240 22 8 24
DN200 1.6Mpa 360 510 340 295 22 12 26

 

2.Thread connection type

Foctur series turbine flow meter Instrument
caliber
(mm)
Nominal
pressure
(Mpa)
L
(mm)
H
(mm)
Thread
specification
(G)
DN4 6.3Mpa 275 260 G1/2
DN6 6.3Mpa 275 260 G1/2
DN10 6.3Mpa 455 260 G1/2
Foctur series turbine flow meter DN15 6.3Mpa 75 265 G1
DN20 6.3Mpa 80 265 G1
DN25 6.3Mpa 100 270 G5/4
DN32 6.3Mpa 140 290 G2
DN40 6.3Mpa 140 290 G2
DN50 6.3Mpa 150 305 G5/2

 

3.Tri-clamp connection type

Foctur series turbine flow meter Instrument
caliber
(mm)
Nominal
pressure
(Mpa)
L
(mm)
H
(mm)
DN25 1.6Mpa 100 275
DN32 1.6Mpa 140 275
DN40 1.6Mpa 140 285
DN50 1.6Mpa 150 300

 

Product • Installation Diagram

Many installation matters need attention |2017 Overall Upgrade | HUAHAI Instrument will display for you

Straight pipe section length of the turbine flowmeter is sensitive to flow velocity distribution distortion and rotational flow in the pipeline, into the sensor should be fully developed turbulent flow, Therefore, according to the spoiler type of upstream of the sensor, to equip the necessary straight pipe section or rectifier, to require the length of the inlet and outlet segments.

Type Installation conditions Type Installation conditions
general condition Foctur series turbine flow meter 90°elbow Foctur series turbine flow meter
Two 90 ° elbows on the same plane Foctur series turbine flow meter Two 90 ° elbows on different planes Foctur series turbine flow meter
Reducing pipe Foctur series turbine flow meter Expanding pipe Foctur series turbine flow meter
Full open valve Foctur series turbine flow meter Half open valve Foctur series turbine flow meter

If the situation of spoiler on the upstream side is not clear, the general recommended the length of upstream straight pipe section not less than 20D, the length of downstream straight pipe section not less than 5D,If the installation control can not meet the above requirements, the rectifier can be installed between the spoiler and the sensor. When the sensor is installed outdoors, there should be measures to avoid direct sunlight and rain-proof.